Pictus 700 Overview

The 700 is a fully automated, random access, floor model analyzer. By utilizing a second reagent tray and second robotic arm, the 700 achieves a throughput of up to 720 tests per hour while occupying minimal space. The unit is extremely economical requiring no external water supply, no 220V electrical requirement, and utilizes reusable cuvettes via an on board wash station. This open system is very flexible and can run most general chemistry and drugs of abuse assays as well. The system is very easy to operate and is ideal for medium to large volume laboratories that require flexibility, high throughput and easy use.

Diatron – Pictus 700 Request For Quote

  • This field is for validation purposes and should be left unchanged.

Features

pdf

  • Efficiency – The Pictus 700 incorporates a 95 position patient sample tray reducing the number of required daily runs. It also has programmable auto dilution for out of range tests. The reagents are very stable requiring few calibrations thus saving time and money. The 72 reagent positions (75 w/ISE) and onboard refrigeration allow for many tests to be kept on the analyzer at the same time.
  • Cost Savings – The 700 does not need an expensive water treatment that requires expensive upfront cost and continual purchase of filters. More savings will be realized by utilizing low cost reagentcalibrator and controls reducing the overall cost per reportable result. Furthermore, the extended service pricing is comparatively low versus other models of this type.
  • Easy to Operate – The Pictus 700 utilizes Windows based software for its operation and is very intuitive with barcoding for sample and reagent identification. It also accepts many sizes of primary tubes. Periodic maintenance is minimal and is easy to perform.
  • Space Utilization – The 700, although a floor model, takes surprisingly little space in the laboratory.
  • Immunoassay
  • ISE
  • Continuous sample loading in removable sectors
  • Liquid level sensors
  • Clot detector
  • External and Internal forced washing
  • Sample/Reagent Mixer
  • Automatic Bar Code recognition
  • Sample volume from 0.2 μl to 100 μl per test
  • Primary tube height up to 100 mm; pediatric tubes
  • Windows environment
  • Interface with LIS
  • For human and veterinary use

Specifications

Throughput
    • Up to 600 tests/hour, max. 720 tests/hour with optional ISE unit
    • 360 test/hour with ISE
Reagents and Sampling System
Samples
    • Sample volume: 2 to 100 μI/tests (in increments of 0.2 μI)
    • Sample tray: 95 (5 racks x 19 positions)
    • ID barcode equipped positions for routine, stat and control samples and standard solutions
    • Primary tube (13 mm diameter, length up to 100 mm)
    • Pediatric vial
    • Blood collection tubes
Reagents
    • Maximum number of simultaneous tests: 36 double to 72 single reagent tests + 3 with optional ISE unit
    • 1to 3 reagents, 2 to 500 μl/tests each (in increments of 1 μl) final total solution volume 180 to 500 μl/test
    • Reagent bottle capacities: 72 cooled positionsI
    • Reagent 2: from 0 to 450 μl
    • Bar code Reader for reagents
Reaction
    • Water consumption: 3L/hour
    • Warm air incubator: room, 30°C an 37°C
    • Reaction cuvette: reusable plastic 6 mm light path cuvettes
    • Reaction time: 0 to 10 min.
    • Reaction temperature: 37°C +/- 0.1°C
    • Mixing: After dispensing each reagent
Optical System
    • Double beam
    • Photometric Range: 0.1 to 3.6 A
    • Measuring wavelengths: 340, 380, 405, 450, 490, 505, 550, 590, 620, 650, 700 and 750 nm
    • Optional filters: 480, 570 nm
    • Photometry – Single or Double wavelength simultaneous reading
Analytical Modes
    • End point with reagent blank
    • Factor or standard calibration modes
    • Priority selection by sample (profile) or by reagent (batch)
    • Calibration curve with up to 10 standards
    • Automatic curve fit
    • Fast and two-point kinetics (zero and first order)
    • Routine, batch, STAT, profiles Enzymes, Drugs, Turbidimetric tests
    • Automatic sample dilution on abnormal levels, excessive substrate consumption and/or lack of linearity
    • Import /export data, methods and historic file, quailty control and calibrator
    • Automatic backup procedure
    • Test selection, automatic calibration, calibration curve, multipoint calibration, polygonal
    • Serum indices: sample blank compensation, calculated tests
    • Quality control, auto re-run, prozone check, record of calibration, data storage (historic results)
    • Automatic pre-dilution and post dilution (ratio 1:5 to 1:100)
    • Stat: Highest priority in operation
    • Continuous sample loading
    • Decontaminating post-wash
Quality Control
    • Full quality control: Levy-Jennings plots, Westgaard multi-rules
Data Management
    • WindowsTM based software
    • Interface LIMS: bi-directional RC 232C, according to ASTM 1394 requirements
Power requirements
    • 110/220 V, 50/60 Hz, 2.0 kVA
Dimensions
    • Size (Width x Depth x Height) 97 x 67 x 100 cm 38.2 x 26.4 x 39.4 in
    • Weight : 115 kg; 253.5 lbs
OPTIONS
  • ISE Unit Na+, K+ and CI measurements on serum or urine samples
  • Barcode reader…Reads all common barcodes used for test requisition and reagent identification.
  • PC Requirements…PC compatible with Celeron 2.4 GHz, 256 MB, RAM, 40GB Hard Disc or bigger, CD ROM, Super VGA 15” Color screen, with Microsoft Windows XP, Vista, Windows 7 Operating system
  • Printers…Most printers supported by Windows can be connected. Printout is optimized by customer: analysis results, work list, patient sample list, quality control, calibration curves, and more.