diatron-pictus-400

Diatron

Pictus 400 Overview

  • Cost Effective – With low instrument cost, low cost reagents, and reusable cuvettes, the P400 provides one of the lowest cost reportable results the industry has to offer.
  • Easy to Operate – The system utilizes Windows based software, barcodes for sample and patient identification, and primary tube sample capability to provide for the ultimate ease of use.
  • Intelligent Sample Management – The multi-function probe offers crash detection, liquid level sensing, while mixing and pre-heat reagents when necessary.
  • Space Saving-The P400 requires only 85 cm of bench space and has a built in power supply. With a depth measuring under 58 cm, it easily fits on most all laboratory counter tops.
  • Large Data Management Capability – QC package includes Levy-Jennings plots and Westgaard rules and stores up to 100,000 patient results on board.

Diatron – Pictus 400 Request For Quote

  • This field is for validation purposes and should be left unchanged.

Features

pdf

Features

  • End Point and Kinetics
  • Stat, Random Access and Batch
  • 280 Test/hour
  • 48 Test on Board
  • 48 Test on Board
  • Automatic Sample Dilution
  • Mixer on Probe
  • Reagent Blank
  • Factor or Non Linear Calibration Curves
  • Barcode Samples & Reagents
  • ISE
  • Immunoturbidimetry
  • Coagulation
  • Quality Control
  • For human and veterinary use

Specifications

Throughput
      • Up to 280 tests/hour depending on configuration

360 test/hour with ISE

Reagents and Sampling System
Samples
    • 48 positions
    • Primary tubes with barcode option
    • Accepts pediatric micro-samples
    • Sample volume: programmable 2–100 μl
    • Continuous loading
    • Sample pre-dilution
Reagents
    • 48 cooled position reagent carousel with barcode reader
    • Open Reagent Test menu
    • Reagent 1: from 0 to 700 μI
    • Reagent 2: from 0 to 450 μl
    • Typical reagent volume: 180 μl
    • Reusable cuvettes
Reaction
    • Reagent probe heater
    • Auto dilution
    • Liquid level sensor
    • Washing outside and inside probe
    • 80 position reaction tray with 5 steps washing station
    • Water consumption: 20 l /10,000 test
    • Warm air incubator: room temp., 30°C and 37°C
Optical System
    • Double beam
    • Wavelengths: 340, 405, 450, 505, 550, 590, 650, 700 and 750 nm, other optional filters available
    • Bandwidth : 10 nm
    • Photometric range: -0.1 to 3.6 A
    • Light source: halogen lamp 6 v – 20 w
Analytical Modes
    • Selection by sample (profile) or by reagent (batch)
    • Up to 10 standards per calibration curve
    • Color reactions
    • Fast and two-point kinetics (zero and first order)
    • Routine, batch, STAT, profiles
    • Enzymes. Drugs.
    • Automatic sample dilution on abnormal levels, excessive substrate consumption and/or lack of linearity
    • Import /export of data, methods and historic file
    • Automatic backup
Quality Control
    • Levy-Jennings plots
    • Westgaard rules
Quality Standards
    • ISO 9001-2000, ISO 13485, CE, EMC, IEC 61010-1
    • Fast and two-point kinetics (zero and first order)
Data Management
    • Multi-tasking Windows based software
    • Interface: bi-directional RS 232C, according to ASTM protocols
Power requirements
    • 85 to 230 VAC, 50/60 Hz, 400 VA
Dimensions
    • Size (Width x Depth x Height) 85 cm x 58 cm x 47 cm 34 in x 18.8 in x 23.2 in
    • Weight: 64 kg, 186 lbs.
OPTIONS
  • ISE Unit Na+, K+ and CI measurements on serum or urine samples
  • Barcode reader…Reads all common barcodes used for test requisition and reagent identification.
  • PC Requirements…PC compatible with Celeron 2,4 GHz, 256 MB, RAM, 40 GB Hard Disc or bigger, CD ROM, Super VGA 15” Color screen, with Microsoft Windows XP, Vista, Windows 7 Operating system
  • Printers…Most printers supported by Windows can be connected.