tosoh-360

TOSOH

AIA 360 Overview

  • Compact Immunoassay Analyzer for Flexible TestingFrom 36 to 200 tests per hour, there is a Tosoh AIA system for every need. The Automated Immmunoassay (AIA) systems are fully equipped to meet the demands of laboratories now and in the future. The accuracy and result integrity of Tosoh products allows for your continued success and growth. Tosoh combines instrument reliability with exclusive AIA-Pack test cups that provide the highest standard of quality, precision and accuracy in clinical diagnostics.
    • Throughput of 36 Results per Hour
    • Easy to Use
    • STAT Assay Results in ~ 20 Minutes
    • Random Access
    • Compact – 16”w x 16”d x 21”h / 61 lbs
    • Full Test Menu of Short Time (ST) Assays
    • Fits Multiple Laboratory Environments:
    • Small hospitals
    • Physician Office Laboratories
    • Cardiac and Specialty Testing
    • Reliable Back-up to Larger Tosoh Analyzers

TOSOH AIA 360 Request For Quote

  • This field is for validation purposes and should be left unchanged.

Features

pdf

System Advantages
    • Icon driven touch screen is intuitive and is easy to navigate
    • Assay monitoring enables the user to check sample progress and assay performance
    • Sample ID’s can be manually programmed if non-barcoded specimens are utilized
    • The system can be interfaced to any LIS system
    • Up to 300 assay results can be saved on the AIA-360
Fast and Accurate Results
    • First result in ~ 20 minutes
    • Bar-code sample ID ensures accurate patient identification without manual worklist entry
    • Analyte is identified via an on-board camera
Convenient Reagent Access
    • The common reagents are easily accessible from the removable reagent tray
    • Reagent level sensors signal the user when reagents are running low or when the waste needs to be emptied
Advanced Sample Carousel
    • The AIA-360 sample carousel holds up to 25 patient samples and 25 test cups at one time
    • The operator may load bar-coded primary tubes or sample cups directly on the system
    • Up to four assays per specimen can be loaded
    • Additional samples and tests can be added at any time without interrupting sample processing
    • Once samples and test cups are loaded, the operator presses START and walks away
Tosoh’s AIA Reagent Test Cup Technology
  • Unit Dose Test Cup reagent technology requires no on-board refrigeration, no pre-mixing and no pre-measuring
  • Saves time and cost by eliminating errors and waste
  • Reagents have a one year shelf life from date of manufacture
  • 90-day calibration curve stability for most assayse
  • Complete test menu includes: Cardiac, Thyroid, Reproductive, Tumor, Metabolic, Anemia and more

Specifications

  • Method…Fluorescence Enzyme Immunoassay
  • Detection…LED illuminant, non flow cell/TOP-TOP photometry method
  • Throughput…36 tests per hour
  • Reaction time…Antigen antibody reaction: 10 minutes
  • Sample loading Capacity…25 samples maximum
  • Reagent loading Capacity…25 tests maximum
  • Test for each sample…4 tests per sample
  • Sampling…Fixed Probe with Clot detection function
  • Sample Vessel…Primary Tube 13 x 75/100mm, 16 × 75/100mm (diameter x length) 2 mL sample cup
  • Barcode…Code39, Code128, ITF, NW-7 and JAN
  • Interface…RS232C
  • Size/Weight…16(W) x 16(D) x 21(H) lnches / 61 lbs. 400(W) x 400(D) x 520(H) mm / 29 kg
  • Power source…AC100-240V. 50/60Hz 250VA
  • Environment…Temperature: 15-30 degrees C, Relative Humidity 40-80%