From 36 to 200 tests per hour, there is a Tosoh AIA system for every need. The Automated Immmunoassay (AIA) systems are fully equipped to meet the demands of laboratories now and in the future. The accuracy and result integrity of Tosoh products allows for your continued success and growth. Ideal for: • Hospitals (all sizes) • Reference labs • Large clinics • Core labs. Three Configurations Provide Expansion Capabilities

TOSOH AIA 900 Series Request For Quote

  • This field is for validation purposes and should be left unchanged.

Features

pdf

 

  • 90 tests/hour throughput
  • Load 10 racks on board
  • Load up to 5 tests/patient
  • First result in ~ 18 minutes
  • Random access
  • Continuous processing
  • Simple touch screen operation
  • Bar-coded primary tube sampling
  • Clot detection
  • Unit Dose Test Cup
  • Automated pretreatment
  • Automated dilution from 2 to 1000

 

AIA-900 with 9 Tray Sorter additional features:
  • Load 9 trays (20 cups/tray)
  • Increased walkaway time – load 180 test cups
  • Load 100 patient samples
AIA-900 with 19 Tray Sorter additional features:
  • Load 19 trays (20 cups/tray)
  • Maximize walkaway time – load 380 test cups
  • Load 100 patient samples

ST-AIA PACK Reagents

Unit Dose Test Cup Technology

Single, unitized cups use a dry reagent format that requires no pre-mixing, no pre-measuring, no on-board refrigeration and creates no waste. Dry reagent format ensures calibration stability of up to 90 days for most assays. Reagents have a one year shelf life from date of manufacture. The AIA test cups and trays are labeled with a test code and lot number for automated scheduling and inventory management on the AIA-900 sorter models. ST AIA PACK reagents provide a faster turnaround time due to a 10 minute incubation protocol. Extensive test menu provides a wide range of immunoassay tests including thyroid, cardiac markers, tumor markers, reproductive hormones, anemia markers, metabolic markers, diabetes, kidney markers and more.

The AIA-PACK test cup format works with every Tosoh AIA Automated Immunoassay System. Reagents are interchangeable, so laboratories with more than one Tosoh system can use the same reagents. Transition between systems is seamless, ensuring consistent results and efficient, economical operation for the laboratory. It is very easy for a lab to add a 9 or 19 tray sorter to the instrument. The reagent’s performance does not change since the analysis section of the instrument remains unchanged.

Specifications

      • Principle of measurement…Fluorescent enzyme immunoassay (FEIA) method
      • Processing method…Fully automated continuous random access
      • Processing ability…Max. 90 tests/hour (ST reagent)
      • Specimen quantity…10 – 125 μL
      • Specimen clogging detection…Pressure detection method
      • Measurement condition…Reaction temperature: 37°C
      • Reaction time…Antigen-antibody reaction time: 10 minutes, 20 minutes, 40 minutes
      • Specimen dilution function…Dilution ratios between 2 and 1000 can be selected for each assay
      • Detection method…Fluorescent measurement (top-top method)
      • Number of sample rack sets…Max. 10
      • Number of samples and reagent cups
      • Max. 100…Specimen containers
      • 13 × 75 mm, 13 × 100 mm, 16 × 75 mm, 16 × 100 mm (O.D. × length of test tube)
      • Dedicated sample cups
      • Specimen barcode…Supports CODE39, CODE128, ITF, NW-7, JAN/EAN/UPC, industrial 2of5, and COOP2of5
      • Sample tip…Dedicated tip
      • Number of installed sample tips…Max. 192 tips (96 tips/rack in 2 racks)

Number of reagent sets…Max. number of reagent vials: 12, Max. number of reagent bottles: 4

    • External output…RS232C
    • Power source/consumption…100 – 240 VAC, 50/60 Hz, 300 VA
    • External dimensions…AIA-900 Loader Model – W/D/H: 35.04” x 26.18” x 49.09”; 890 mm x 665 mm x 1247 mm
    • AIA-900 with 9 Tray Sorter – W/D/H: 50.79” x 26.18” x 49.09”; 1290 mm x 665 mm x 1247 mm
    • AIA-900 with 19 Tray Sorter – W/D/H: 59.84” x 26.18” x 49.09”; 1520 mm x 665 mm x 1247 mm
    • Temperature…15 °C – 30 °C (degrees Celsius)
    • Humidity…40 % – 80 % R.H. (non-condensing)
    • EMC standard…IEC61326-1: 2005, IEC61326-2-6: 2005
Dimensions:
  • AIA-900 Loader Model…35.04 (W) x 26.18 (D) x 49.09 (H) inches 890 (W) x 665 (D) x 1247 (H) mm
  • AIA-900 with 9 tray sorter…50.79 (W) x 26.18 (D) x 49.09 (H) inches 1290 (W) x 665 (D) x 1247 (H) mm
  • AIA-900 with 19 tray sorter…59.84 (W) x 26.18 (D) x 49.09 (H) inches 1520 (W) x 665 (D) x 1247 (H) mm