The DxH 690T is a bench-top hematology analyzer that delivers trusted results for mid-volume labs. With this table-top configuration, you can count on best-in-class hematology technology, minimal slide reviews, maximum efficiency, and significant cost savings.
Trust your results—the first time—with a high-quality benchtop hematology analyzer that delivers precise, accurate results and advanced cellular insights.
Free up your mid-size laboratory’s hematology team and empower your busy staff to focus on samples and tasks that truly need attention.
Tap into powerful savings to help your lab devote time, budget, and resources where they are needed most.
Methodology |
Enhanced Coulter Principle, VCS 360 with DataFusion | |||||
ParametersEmpty heading
|
CBC: WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW, RDW-SD, PLT, MPV Differential: NE%, LY%, MO%, EO%, BA%, NRBC%, NE#, LY#, MO#, EO#, BA#, NRBC# Retic: RET, RET#, MRV, IRF Body Fluids (Cerebrospinal, Serous, or Synovial): RBC, TNC |
|||||
Throughput (tests per hour) |
Up to 100 samples/hour | |||||
Sample Volumes |
Whole Blood: 165 μL aspiration volume. Predilute: 50 μL whole blood into 200 μL of diluent | |||||
Analytical Measuring Ranges1 |
Whole Blood (CBC) | |||||
Parameters | Units | Analytical Measuring Range | ||||
WBC | x103 cells/μL | 0.050–400.000 | ||||
RBC | x106 cells/μL | 0.005–8.500 | ||||
HGB | g/dL | 0.10–25.50 | ||||
MCV | fL | 50.00–150.00 | ||||
RDW | % | 10.00–40.00 | ||||
RDW-SD | fL | 15.00–150.00 | ||||
PLT | x103 cells/μL | 3.0–3000.0 | ||||
MPV | fL | 5.00–25.00 | ||||
Body Fluids | ||||||
TNC | cells/mm3 | 20–89,000 | ||||
RBC | cells/mm3 | 1,000–6,200,000 | ||||
Data Management |
Up to 50,000 patient results with histograms, scatter plots, and demographics
100,000 patient results with graphics for power computer |
|||||
Quality Assurance |
QC with Levy-Jennings graph; XB/XM for moving averages, daily check, intelligent quality monitoring, MRV, IRF, customizable calibration and QC reminders and alerts, auto export of QC | |||||
Acoustic Noise Level |
≤ 60 dBa | |||||
Radio Frequency and Interference Immunity |
Meet the product level standards EN 61326-1 (Electrical Equipment for Measurement, Control, and Laboratory Use—EMC Requirements), and EN 61326-2-6 (Part 2, Specific Requirements for In-Vitro Diagnostic Devices) | |||||
Power Consumption |
DxH 690T SPM: 520 W (1775 BTU/hour), Monitor: 35 W (120 BTU/hour), DxH Power Computer: 160 W (546 BTU/hour) | |||||
Dimensions and weight2 |
Width | Height | Depth | Weight | ||
76.2 cm (30 in.) | 90.17 cm (35.5 in.), with cover closed
113.03 cm (44.5 in.), with cover open |
83.82 cm (33 in.), including the removable back panel
80 cm (31.5 in.), excluding the removable back panel |
~141.97 kg (313 lbs.), including monitor ~136.98 kg (302 lbs.), |
|||
Additional Clearance |
15.2 cm (6.0 in.) per side of instrument for troubleshooting; 3.8 cm (1.5 in.) behind instrument for sufficient cooling |
Service |
New Preventative Maintenance (PM) schedule with customer care visits |
Support |
Onboard IFU and Instructional Videos, Automated QC and calibration reminders, PROService |
Analyzer Downtime |
Minimum of 30 minutes in cleaner every 24 hours with automatic daily checks |
Available RUO Parameters3Empty heading |
BFM, BFM#, BFP#, EGC, EGC#, HLR, HLR#, LHD, MAF, MSCV, PCT, PDW, RDWR, RDWR-SD, RSF, UGC, UGC#, UWROP, WDOP, WNOP, WROP, CPD (refer to reference 3 for additional RUO parameters) |
Research Use Only. Not for use in In Vitro Diagnostic procedures.
1. DxH 690T IFU (PN C06947)
2. DxH 690T ReadMe (PN C53971)
3. DxH 690T RUO Addendum